2 x 125 A 8 modules 15 connections distribution block • BD125152

This product has been added to the quote request!

Home Assembly and cabling Distribution blocks 2 x 125 A 8 modules 15 connections distribution block

BD125152

2 x 125 A 8 modules 15 connections distribution block

Sold individually, in packs of 20

This product has been added to the quote request!

Autres modèles bipolaires disponibles en 125 A

7 connections 11 connections

Description

Modular distribution blocks are used to bring together incoming and outgoing electrical circuits at a single point. They are used in tertiary, industrial and photovoltaic applications.

This 125 A rated bipolar modular terminal block has 15 connections per phase. The operating voltage is 1000 Vac/dc.

The Zelec range of distribution blocks extends from 40 A to 160 A in the bipolar and quadripolar versions. They can be snapped onto DIN rails and are sold with adapters for mounting onto base plates. Incoming and outgoing cables are flexible cables with ferrules or rigid cables. Their sloping bars make them easy to connect. The removable base ensures the safety of property and people.

Technical characteristics

Manufacturer
Zelec
Rated current
125 A
Number of connections per phase
15
Number and diameter of holes
1 x Ø9 mm, 2 x Ø8 mm, 2 x Ø6.9 mm, 10 x Ø6 mm
Flexible cables with ferrules
1 x 6 to 35 mm²
2 x 4 to 25 mm²
2 x 2.5 to 16 mm²
10 x 1.5 to 10 mm²
Rigid cables
1 x 10 to 35 mm²
2 x 6 to 25 mm²
2 x 4 to 16 mm²
10 x 2.5 to 10 mm²
Number of modules
8
Insulation voltage
1000 Vac/dc
Pulse voltage (Uimp)
8 kV
Permissible rated peak withstand short-circuit current
22 kA
Effective rated short-time withstand short-circuit current
6 kA
Usage frequency
50/60 Hz
Mounting
DIN rail or plate
Height
45 mm
Width
134 mm
Length
47 mm
Weight
208 g
Colour
Transparent
Materials
Screws: galvanised steel
Terminal block: high-conductivity brass
Structure: polyamide and polycarbonate
Operating temperature
-5°C to +85°C
Storage temperature
-10°C to +100°C
Standards
IEC 60998-1 : 2004
Packaging
20 units
Minimum order
1 unit
Accessories
This distribution block can accommodate an additional terminal strip for the neutral conductor
=

A rated short-time withstand current that is among the highest on the market

For your installation to be compliant, the splitter’s rated short-time withstand current must be greater than or equal to the short-circuit current.

Our range of distributors offers a rated short-time withstand current of up to 13 kA, covering most applications on the market.

The rated short-time withstand current is the ICW. This current relates to the busbars.

The Icc is the value of the short-circuit current. This value is essential for switchboard design (the intensity of the short-circuit current given by the transformer power, the length of the cables, their diameter, etc.).

1
=

Reinforced insulation between phases

The splitter is supplied with a removable base.

This makes:

  • installing it easier: the product can be cabled up before being installed on the rail or base plate
  • DIN rail protection of a size perfectly adapted to the product possible – no cutting is required

In addition, the insulation between each phase prevents accidental direct contact, ensuring perfect insulation between each phase.

2
=

Easy cover opening

The soft plastic protective cover makes opening and closing it easy. It can be removed at the touch of a finger and requires no tools.

Handling is also possible in a cramped environment, such as when the distribution block is located under a wiring duct, for example.

3
=

35 mm² wiring

Unlike those of other manufacturers, our splitter is designed with 9 mm diameter inputs. This means it can be wired with 35 mm² cables with terminators, meaning that the product can be supplied in a 125 A version and avoiding the need for a 160 A splitter.

4
1 2 3 4

Associated products