BC125164
4 x 125 A 12 modules 16 connections side input distribution block
Sold individually, in packs of 6
Other quadripolar models available in 125 A versions
Description
Modular distribution blocks are used to bring together incoming and outgoing electrical circuits at a single point. They are used in tertiary, industrial and photovoltaic applications.
This 125 A rated quadripolar modular terminal block has 16 connections per phase. The operating voltage is 1000 Vac/dc.
The Zelec range of distribution blocks extends from 40 A to 160 A in the bipolar and quadripolar versions. They can be snapped onto DIN rails and are sold with adapters for mounting onto base plates. Incoming and outgoing cables are flexible cables with ferrules or rigid cables. Their sloping bars make them easy to connect. The removable base ensures the safety of property and people.
We give you the option to increase the number of neutral connections on all the quadripolar distribution block from our range.
Technical characteristics
2 x 4 to 25 mm²
2 x 2.5 to 16 mm²
11 x 1.5 to 10 mm²
2 x 6 to 25 mm²
2 x 4 to 16 mm²
11 x 2.5 to 10 mm²
Terminal block: high-conductivity brass
Structure: polyamide and polycarbonate
A rated short-time withstand current that is among the highest on the market
For your installation to be compliant, the splitter’s rated short-time withstand current must be greater than or equal to the short-circuit current.
Our range of distributors offers a rated short-time withstand current up to 13 kA, covering most applications on the market.
The rated short-time withstand current is the ICW. This current relates to the busbars.
The Icc is the value of the short-circuit current. This value is essential for switchboard design (the intensity of the short-circuit current given by the transformer power, the length of the cables, their diameter, etc.).
Easy to connect
The distribution block in the Zelec range are designed with sloping bars, making them easy to connect. The installer can easily and quickly reach the product’s last bars.
Reinforced insulation between phases
The splitter is supplied with a removable base.
This makes:
- installing it easier: the product can be cabled up before being installed on the rail or base plate
- DIN rail protection of a size perfectly adapted to the product possible – no cutting is required
In addition, the insulation between each phase prevents accidental direct contact, ensuring perfect insulation between each phase.
Easy cover opening
The soft plastic protective cover makes opening and closing it easy. It can be removed at the touch of a finger and requires no tools.
Handling is also possible in a cramped environment, such as when the distribution block is located under a wiring duct, for example.
35 mm² wiring
Unlike those of other manufacturers, our distribution blocks is designed with 9 mm diameter inputs. This means it can be wired with 35 mm² cables with ferrules, meaning that the product can be supplied in a 125 A version and avoiding the need for a 160 A splitter.
Simple cabling
Thanks to its side and separate inputs, the largest diameter is at the end of the distribution block, which makes it easy to cable the inputs. A considerable time-saver for all installers.
Associated products
BDT48
48 connections earth bar L 461.5 mm
2 Other sizes available
EM380PURS
80 A 4 modules, Modbus RS485 3 phase + N multimesurement direct energy meter
3 Other models available in 3 phase models
VC05-0296
2.5 to 50 mm² 1000 V for Cu / Al for cable grey power terminal block
2 Other colours available
BBD16011
4 x 160 A 11 connections multi-stage distribution block (supplied assembled)
2 Other models available in 160 A versions
VG03-0006
160/200 A Al / Cu, 6 Cu outputs single pole distribution block
2 Other sizes available
Assembly and cabling