My quote (0)

No products selected

Validate my quote
4 x 125 A 9 modules 10 connections side input distribution block • BC125104

This product has been added to the quote request!

Home Assembly and cabling Distribution blocks 4 x 125 A 9 modules 10 connections side input distribution block

BC125104

4 x 125 A 9 modules 10 connections side input distribution block

Sold individually, in packs of 8

This product has been added to the quote request!

Other quadripolar models available in 125 A versions

7 connections 11 connections 15 connections 16 connections

Description

Modular distribution blocks are used to bring together incoming and outgoing electrical circuits at a single point. They are used in tertiary, industrial and photovoltaic applications.

This 125 A rated quadripolar modular terminal block has 10 connections per phase. The operating voltage is 1000 Vac/dc.

The Zelec range of distribution blocks extends from 40 A to 160 A in the bipolar and quadripolar versions. They can be snapped onto DIN rails and are sold with adapters for mounting onto base plates. Incoming and outgoing cables are flexible cables with ferrules or rigid cables. Their sloping bars make them easy to connect. The removable base ensures the safety of property and people.

Technical characteristics

Manufacturer
Zelec
Rated current
125 A
Number of connections per phase
10
Number and diameter of holes
1 x Ø9 mm, 2 x Ø8 mm, 2 x Ø6.9 mm, 5 x Ø6 mm
Flexible cables with ferrules
1 x 10 to 50 mm²
2 x 6 to 35 mm²
2 x 4 to 25 mm²
5 x 2.5 to 16 mm²
Rigid cables
1 x 16 to 50 mm²
2 x 10 to 35 mm²
2 x 6 to 25 mm²
5 x 4 to 16 mm²
Number of modules
9
Insulation voltage
1000 Vac/dc
Pulse voltage (Uimp)
8 kV
Permissible rated peak withstand short-circuit current
22 kA
Effective rated short-time withstand short-circuit current
6 kA
Usage frequency
50/60 Hz
Mounting
DIN rail or plate
Height
45 mm
Width
151 mm
Length
107 mm
Weight
394 g
Colour
Transparent
Materials
Screws: galvanised steel
Terminal block: high-conductivity brass
Structure: polyamide and polycarbonate
Operating temperature
-5°C to +85°C
Storage temperature
-10°C to +100°C
Standards
IEC 60998-1 : 2004
Packaging
8 units
Minimum order
1 unit
Accessories
This distribution block can accommodate an additional terminal strip for the neutral conductor
=

A rated short-time withstand current that is among the highest on the market

For your installation to be compliant, the splitter’s rated short-time withstand current must be greater than or equal to the short-circuit current.

Our range of distributors offers a rated short-time withstand current up to 13 kA, covering most applications on the market.

The rated short-time withstand current is the ICW. This current relates to the busbars.

The Icc is the value of the short-circuit current. This value is essential for switchboard design (the intensity of the short-circuit current given by the transformer power, the length of the cables, their diameter, etc.).

1
=

Easy to connect

The distribution block in the Zelec range are designed with sloping bars, making them easy to connect. The installer can easily and quickly reach the product’s last bars.

2
=

Reinforced insulation between phases

The splitter is supplied with a removable base.

This makes:

  • installing it easier: the product can be cabled up before being installed on the rail or base plate
  • DIN rail protection of a size perfectly adapted to the product possible – no cutting is required

In addition, the insulation between each phase prevents accidental direct contact, ensuring perfect insulation between each phase.

3
=

Easy cover opening

The soft plastic protective cover makes opening and closing it easy. It can be removed at the touch of a finger and requires no tools.

Handling is also possible in a cramped environment, such as when the distribution block is located under a wiring duct, for example.

4
=

35 mm² wiring

Unlike those of other manufacturers, our distribution blocks is designed with 9 mm diameter inputs. This means it can be wired with 35 mm² cables with ferrules, meaning that the product can be supplied in a 125 A version and avoiding the need for a 160 A splitter.

5
=

Simple cabling

Thanks to its side and separate inputs, the largest diameter is at the end of the distribution block, which makes it easy to cable the inputs. A considerable time-saver for all installers.

6
1 2 3 4 5 6

Associated products